Effect of allowable flow-rate variation and local head loss on maximum length of non-pressure compensated drip tape

  • Luiz Antonio de Andrade Consultor autônomo. Alameda Frida Elza Scheuber Brantes, n° 651, CEP: 18705-790, Avaré, SP, Brazil.
  • João Carlos Cury Saad Faculdade de Ciências Agronômicas. Departamento de Engenharia Rural e Socioeconomia. Universidade Estadual Paulista "Júlio de Mesquita Filho" (UNESP), Avenida Universitária, nº 3780, CEP: 18610-034, Botucatu, SP, Brazil.
  • Bruno Marcos Nunes Cosmo Faculdade de Ciências Agronômicas. Departamento de Engenharia Rural e Socioeconomia. Universidade Estadual Paulista "Júlio de Mesquita Filho" (UNESP), Avenida Universitária, nº 3780, CEP: 18610-034, Botucatu, SP, Brazil.
  • João Victor Costa Faculdade de Ciências Agronômicas. Departamento de Engenharia Rural e Socioeconomia. Universidade Estadual Paulista "Júlio de Mesquita Filho" (UNESP), Avenida Universitária, nº 3780, CEP: 18610-034, Botucatu, SP, Brazil.
  • Willian Aparecido Leoti Zanetti Faculdade de Ciências Agronômicas. Departamento de Engenharia Rural e Socioeconomia. Universidade Estadual Paulista "Júlio de Mesquita Filho" (UNESP), Avenida Universitária, nº 3780, CEP: 18610-034, Botucatu, SP, Brazil.
Keywords: emitter head loss, lateral line length, uniformity.

Abstract

A challenge for the design of drip irrigation systems with non-pressure compensated emitters is to increase the maximum length of the lateral lines without significantly reducing water application uniformity. This work evaluated the effect of the flow-rate variation and the local head loss in the maximum length of drip tape with a non-pressure compensated flat emitter. The tests were carried out in a laboratory, using a collapsible drip tape non-pressure compensated in three 50-meter segments. The production line was configured to generate drip tapes without insertion of emitters and with closed emitters (0.30 m spacing). The experimental local head loss was compared with the Darcy-Weisbach equation's estimates using the Blasius friction factor. In the sequence, simulations were generated for the flow-rate variations of 10 and 20% for the emitter spacings of 0.30, 0.40, and 0.50m. The results showed that the local head loss had little influence on the lateral line's maximum length, generating variations of 2.5% on average. However, increasing the allowable flow rate variation from 10 to 20% resulted in a 34% increase in the lateral line maximum length. Also, the reduction in uniformity coefficients was less than 5%, enabling the indexes to remain above 90%. The adoption of higher flow rate variation values allowed gains in the lateral line length with a small decrease in uniformity, making it an alternative to reduce design and operational costs.